• 7.75kV 475kVar High Voltage Power Factor Capacitor Bank
7.75kV 475kVar High Voltage Power Factor Capacitor Bank
discuss personally
Model
BAM7.75-475-1W
Basic info
Brand ROCKWILL
Model NO. 7.75kV 475kVar High Voltage Power Factor Capacitor Bank
Rated voltage 7.75KV
Rated frequency 50/60Hz
Series BAM
Product Detail

Overview

 The shunt capacitor is composed of a pack, a case, an outlet porcelain busing, etc. The two sides of stainless steel case are welded with hanging brackets for installation, and one hanging bracket is equipped with a grounding bolt. In order to adapt to various voltages, the pack is composed of several small elements connected in parallel and series. The capacitor is equipped with a discharge resistor.

Main features

  • Casing: Cold-pressed, anti-fouling type casing is adopted, and the creepage distance is not less than 31mm/kV.

  • Mature internal fuse technology.

  • After testing, the internal fuse can isolate the faulty component within 0.2ms, the release energy of the fault point is not more than 0.3kJ, and the remaining intact components are not affected.

  • Advanced concealed internal fuse structure, using oil gap arc extinguishing, reducing the possibility of blasting the capacitor case.

  • The internal fuse protection and relay protection have perfect coordination standards to ensure the safe and reliable operation of the entire device.

  • Liquid medium: 100% insulation oil (NO PCB) is used. This liquid has excellent low temperature performance and partial discharge performance.

  • The main insulation adopts a composite insulation structure, which not only guarantees excellent electrical performance, but also has a certain degree of mechanical strength, which ensures that the insulation of the capacitor complete set of devices is 100% reliable without protection.

  • Good sealing performance: The annual leakage rate is less than 0.1%, and the sealing performance of the capacitor is guaranteed through measures such as automatic argon arc welding, vacuum leak testing, and thermal aging.

  • Partial discharge level: the extinguishing voltage is not less than 1.5Un, and each capacitor is tested for partial discharge during production.

Parameters

 Medium voltage shunt capacitor/High voltage shunt capacitor are suitable for 50Hz or 60Hz AC power systems to improve the power factor of the power system, reduce line losses, improve the quality of the power supply voltage, and increase the active output of the transformer.

Rated Voltage:

7.75KV

Rated Current:

61.29A

Rated Capacitance:

25.17uF

Rated Capacity:

475kVar

Rated Frequency:

50/60Hz

Protection Method:

No Internal Fuse

Number Of Phases:

Single-phase

Capacitance Deviation:

-3%~+3%

Material:

Stainless Steel



 

Rated voltage

7.75KV

Rated frequency

50/60Hz

Rated Capacity

475 kvar

Insulation level

28/125kV

Protection method

No internal fuse

Number of phases

Single-phase

Capacitance deviation

-3%~+3%

Package

Export standard packing

Loss tangent value (tanδ)

≤0.0002

Discharge resistance

The capacitor is equipped with a discharging resistor. After being disconnected from the grid, the voltage on the terminal can drop below 50V within 5 minutes

Conditions of  Operation

  • Altitude:Less 1000m;Ambicnt Temperature:-40℃ to 40℃.

  • No violcnt mcchanical vibration, no harmful gas and vapor ,no electric,and cxplosive dust in location.

  • Power capacitor will work in the good ventilate condition, it would not permit to work in sealing and no ventilate condition.

  • Power capacitor connection wire should take soft conductive wire, the whole circuit connect well.

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
1.Flame-Retardant Cable Classification StandardsThe flame-retardant standard system is divided into two main categories. The first category follows the "Classification of Burning Behavior for Electric and Optical Fiber Cables" GB 31247. Cables complying with this standard system are widely used in densely populated areas such as high-speed railways and subways. This standard imposes strict requirements on parameters such as smoke density, heat release, and total smoke production, and cables typi
James
09/03/2025
Repair of high-voltage cable metallic sheaths
Repair of high-voltage cable metallic sheaths
I. Functions of Metallic Sheaths and Necessity of RepairThe metallic sheath of high-voltage cables is a metal shielding structure laid outside the insulation layer, including types such as lead sheaths, aluminum sheaths, and steel wire armor. Its core functions include mechanical protection (resisting external impact and compression), electrochemical corrosion protection (isolating moisture and soil pollutants), electromagnetic shielding (reducing electromagnetic interference to the environment)
Felix Spark
09/03/2025
What factors need to be considered when designing a transformer?
What factors need to be considered when designing a transformer?
Transformer design is a complex process that requires consideration of multiple factors to ensure safe and efficient operation. In addition, compliance with international and local regulations is essential to guarantee that transformers meet safety and performance standards. Below are key factors to consider in transformer design and the relevant regulations to follow:Transformer Design Factors: Voltage and Frequency: Determine the input and output voltage levels and the operating frequency. The
Vziman
09/02/2025
What failure modes are possible in a transformer? How to identify and fix these failures?
What failure modes are possible in a transformer? How to identify and fix these failures?
Transformers are critical components in power systems, and various failure modes can affect their operation. Timely identification and resolution of these failure modes are essential to prevent costly downtime and ensure system reliability. Below are some common transformer failure modes, along with methods to identify and address them: Insulation FailureIdentification: Insulation failure leads to decreased insulation resistance, which can be detected through insulation resistance testing (megge
Edwiin
09/02/2025
A hybrid DC circuit breaker
A hybrid DC circuit breaker
Most DC molded-case circuit breakers use natural air arc extinction, and there are typically two arc extinguishing methods: one is conventional opening and closing, where the contacts axially stretch the arc, while the conductive circuit generates a magnetic field that bends and elongates the arc, pulling it lengthwise perpendicular to the arc axis. This not only increases the arc length but also induces lateral motion, enabling air cooling to achieve arc extinction.The other method involves the
Echo
09/02/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!